Availability – A Design Parameter
for The Super 400 UPS System
• No Single Point Failure Mode:
The Parallel Redundant configuration of Super
400 has separate Input Circuit Breakers, Magnetics,
Power Supplies and Separate Battery Banks,
which further enhance UPS availability.
• Charger / Inverter Redundancy :
The Parallel Redundant Super 400 System has
cross Redundancy. If the charger of one module
and
the inverter of the other module both fail
together, the load continues to get clean
UPS power through the working charger and
inverter.
• Control Circuit Redundancy :
The Parallel Redundant Super 400 System has
two independent control circuits.
• Designed for Indian Conditions:
The Super 400 UPS System is designed considering
poor power conditions prevalent in the Country.
The Super 400 tolerates wide input voltage
[ -30% /+25% ] and frequency [ +/- 10% ] variations.
• Extensive Beta Testing : The
Super 400 has been site tested at multiple
locations all across the Country having extreme
power conditions and has proved successful
at all such sites.
• Validation Test & Torture Test
: The Super 400 is design validated and
torture tested at elevated temperatures of
50 degrees Celsius
without any derating of output power. The
Super 400 is also torture tested with various
extreme simulated power conditions as recorded
at various sites in the Country, using California
Instrument Power Source Generator.
Advanced Hardware Features
• Built in Parallel Redundancy :
Each Super 400 can be connected in parallel
to another Super 400 of the same output, voltage
and kVA rating without the need for any additional
card or other accessories.
• Wide Input Voltage window [-30%%
and +25%] and Wide Input Frequency window
[+/-10%]: Allows the Super 400 to function
reliably on mains despite wide voltage and
frequency fluctuations at the input.
• Cold/ Black Start Capability :
Super 400 can be directly started on batteries
in the absence of mains supply.
• Flexibility to connect various battery
types : The Super 400 can use various
types of batteries including SMF, Lead Acid
Tubular and Ni-Cd batteries.
• Online Battery Testing and Temperature
Compensated Battery Charging : The Super
400 warns of any impending battery problems.
In the case of SMF batteries the charging
current is controlled based on the ambient
temperature so as to provide optimum charging,
thus protecting the life of the batteries.
• Built in LED/ LCD display :
A comprehensive array of LED/ LCD display
provides information on the status of the
UPS, allows parameter monitoring, event logging
upto 200 events, system settings and controls.
Advanced Firmware Features
• Each Super 400 module uses Dual Micro
Controllers – HITACHI H8/ 3048F –
providing On-board Programmability.
• The Dual Micro Controllers are used
for Control and Communication functions respectively.
Advanced Software Features
• The Super 400 provides advanced software
options for communication.
- SiteNet 1 : Auto shutdown software for virtually
all networking operating systems
- SiteNet 2 : Auto shutdown and power monitoring
software for virtually all networking operating
systems
- Netcom : The Netcom Card is an optional
feature used for monitoring the UPS status
through Internet / WAN/ MAN/LAN.
- Data Logger Software : Offers parameter
/ event monitoring on local PC
Also Featuring:
• Built in Parallel Redundancy
• Wide Input Voltage and Wide Input Frequency
Window.
• Cold / Black Start Capability.
• Compatible with various battery types.
• LED / LCD Display.
• Online battery testing.